How to Read Nullifire's Unique Reference Numbers in 8 Steps!

How to Read Nullifire's Unique Reference Numbers in 8 Steps!

You may be familiar with Nullifire's new Technical Drawing Details by now and they hope you’re finding these useful. Each of these documents contain a unique reference number, which you might not find very intuitive at first. This number serves as a key point for our Technical team's future interactions, enabling precise communication and problem-solving.

So, as promised, in this article Nullifire delve into the art of reading and interpreting these unique reference numbers in 8 steps, to empower you to navigate their technical documentation effortlessly.

1. Main Product

This refers to Nullifire's 5 digits product shortcut, for example:

FB750
FS709
FS702
FP302
FP170

2. Substrate plus minimum thickness in mm

The substrate can be as per below:

• DW =Drywall
• RW = Rigid Wall
• CF = Concrete Floor
• PC = Plasterboard Ceiling
• MS = Multiple substrates

3. FB750 Construction Type (only when applicable)

The construction types refer to:

• SC = Single Batt Compressed DC = Double Batt Compressed DP = Double Batt Pattress CP = Compressed + Pattress
• BB = Batt box

4. Single / Multiple or Mixed Penetrations

Represented as:

• SI = Single
• MU = Multiple
•MI = Mixed

5. Penetration Type

Which are numbered as per below:

• Combustible pipe
• Non Combustible pipe
• Non Combustible pipes insulated
• Cables / Cable carriers
• Blank seals
• Dampers

6. The Second main product (when applicable) (5 digits)

This again, refers to Nullifire's 5 digits product shortcut, for example:

FS709
FP302
FP170
FI025

7. Unique number

And last but not least,

8. Type of document

At the moment this refers to:

• TD = Technical detail
• 3D = 3D detail
• 2D = 2D detail

Let's go through a few examples for better understanding…

FB750-DW100-DP-SI-01-00001-TD

This reference number refers to: FB750 - drywall 100 mm – double batt pattress – Combustible pipe - single penetration - technical detail.

FB750-DW100-DC-SI-04-FS709-00001-TD

This second example reads as follow: FB750 - drywall 100 mm – double batt compressed - cable – single penetration – cables - second product – technical detail.

Nullifire believe that by enhancing the availability and clarity of technical information, they contribute to raising the bar for fire stopping and safety standards across the industry.

All of Nullifire's technical documents, including the new Technical Drawing Details are available to download, for free, from the website – www.nullifire.com.

At Nullifire, they're not just providing fire protection solutions; they are providing you with the knowledge and tools you need to safeguard lives and buildings.

For further information, please get in touch today.

Add to Project Board

Create a new project board:


Nullifire

Nullifire

For over 50 years, Nullifire has built its reputation on the quality of its service as well as its outstanding smart passive fire protection products.

The only manufacturer to offer both intumescent steel coatings and fire stopping...
View company profile
T01942 251 400
Ehello@tremcocpg.com
WVisit Nullifire's website
 Tremco CPG UK Limited, Coupland Road, Hindley Green, Wigan, Greater Manchester, WN2 4HT

Make an enquiry to Nullifire

You may also be interested in this related Company News: The Crucial Role of Passive Fire Protection and Fire Stopping in Schools Read Now
Subscribe to the Barbour Product Search newsletter