The use of non-combustible materials: what the law states [BLOG]

The use of non-combustible materials: what the law states [BLOG]

This blog was written by Alfresco Floors Limited

Building Regulations have prohibited the use of combustible materials in external walls on “relevant buildings” and “specified attachments” above 18 metres; these regulations have been in place since December 2018. Despite this, however, there is still uncertainty surrounding the nature of these requirements.

This blog sets out to clarify current legislation surrounding the use of non-combustible materials in high-rise buildings.

Checking Fire Performance Characteristics of Materials

Architects, specifiers - and any individual responsible for the sourcing of materials – should carefully check fire performance characteristics on key products making up the external wall construction.

Additionally, you should seek certification for fire performance on any "specified attachment" in detail. It’s important to note, however, that materials classified as A1 Fire-Rated do not require a fire rating certificate. We will further explain this later in the article.

The European Classification System for Fire Performance

The introduction to the European Classification System ensures a common method for comparing the Reaction to Fire performance of construction products across a wide range of European countries.

For wall and ceiling insulation, materials are given a Reaction to Fire Classification of either A1, A2, B, C, D, E and F; ‘A1’ meaning entirely non-combustible, with ‘F’ meaning highly combustible.

Alongside this, there are additional criteria that provides information on a product’s tendency to produce smoke and flaming droplets or particles. This is measured by three smoke intensity levels: s1, s2 and s3, with s3 being the worst.

Additionally, burning droplets/particles are measured for Reaction to Fire classes A2 to E. There are three classes of burning droplets: d0, d1 and d2, with d2 being the worst.

To paraphrase Fire safety: Approved Document B, Regulation 7 (2),

Materials in an external wall or specified attachment (including balconies and sun shading) [should] have European classification A1 or A2-s1,d0 (for relevant buildings over 18 metres), including where the project is a change of use.

Taking this into consideration, specifiers working on high rise projects must source materials with an A1 or A2 fire-rating.

What Is the Difference Between A1 and A2 Fire Rating?

Whilst both A1 and A2 falls into the ‘non-combustible’ category and can thus be specified in high rise buildings, there is a significant difference between the two ratings.

A1-rated materials cannot contribute to a fire at any stage, including a fully developed fire. Therefore, this would never be combined with additional classification.

A2-rated materials, on the other hand, may produce no contribution to fire but such materials do have the potential to produce some smoke or flaming droplets. This is then followed by an additional classification for smoke and droplets – as mentioned above.

When comparing A1 and A2-rated materials, the key difference is the production of smoke – which is apparent in A2-rated materials. The Home Office of National Statistics 2019 identified that over 34% of fire-related deaths were caused by gas or smoke inhalation.

Whilst both A1 and A2 materials are classified as non-combustible - and can be specified for external applications and specified attachments – A1 rated materials offer that added element of security and safety.

A1 Fire-Rated Materials: Some Examples

For architects, designers and specifiers working on a ‘specified attachment’ such as a balcony, walkway, terrace, roof or winter garden, it’s important to understand the different materials that are classified as A1 Fire-Rated. The following materials/products all fall into the A1-rated Aluminium decking.

• Porcelain pavers
• Concrete pavers
• Natural stone pavers

A1 Fire-Rated Pedestals and Subframes For High-Rise Projects

When working on a specified attachment for a high-rise project, it’s crucial that all components of the flooring are A1 rated – meaning that pedestals and subframes should be non-combustible, too.

In this instance, we recommend a pedestal made from 100% aluminium, such as the A-PED™ and a subframe such as the REIF DuraLink® system
When used alongside the surface materials mentioned above, you are providing a fully A1-rated solution.

Conclusion

Now, more than ever, there’s a need to provide a solution-driven by safety to ensure that mistakes from the past remain in the past.

With the new Building Regulations in play, it’s crucial that we all sing from the same hymn sheet, and we aim to help aid the specification process for any high-rise project.

Add to Project Board

Create a new project board: